4 Nov – Three-year outcomes from the investigator-initiated, multicentre SIRONA randomised trial demonstrate that the Concept Medical MagicTouch PTA sirolimus-coated balloon (SCB) achieves a higher rate of freedom from clinically driven target lesion revascularisation (cdTLR) versus paclitaxel-coated balloon (PCB) in patients with femoropopliteal disease. No between-group differences were observed in walking capacity, quality of life or safety endpoints.
https://www.conceptmedical.com/magictouch-pta/
Presented by principal investigator Prof. Ulf Teichgräber (University Hospital Jena, Germany) as a Late-Breaking Clinical Science report at TCT 2026, the findings were simultaneously published in JACC: Cardiovascular Interventions. SIRONA is the first randomised trial comparing these two technologies with follow-up beyond two years.
Conducted across 25 centres in Germany and Austria, SIRONA enrolled 482 symptomatic femoropopliteal disease patients (96.3% intermittent claudication). After successful pre-dilation, participants were randomised 1:1 to SCB or PCB angioplasty. The trial previously met its 12-month primary non-inferiority endpoints for patency and safety.
At three years, freedom from cdTLR was 88.2% in the SCB arm versus 80.2% in the PCB arm (absolute difference 8.0 percentage points; 95%CI:1.0–14.8; P=0.01; HR=0.60, 95%CI:0.36–0.97; log-rank P=0.03). Kaplan–Meier curves diverged after Year 1. Improvements in patient-reported walking distance and quality of life persisted to three years with no intergroup difference. Safety profiles were comparable: all-cause mortality 7.4% in both arms (HR=1.16, 95%CI:0.59–2.28). Major amputation was rare (1 SCB, 2 PCB); amputation-free survival was 92.1% and 92.2%, respectively. Freedom from clinically driven target vessel revascularisation did not differ significantly (83.8% vs 79.1%; P=0.27).
These data emerge amid renewed scrutiny of paclitaxel-coated devices following SWEDEPAD 2, which informed 2026 ESCVS guidance recommending cautious use in intermittent claudication. Investigators note the trial was powered for the 12-month primary endpoint; the three-year analysis is exploratory and the cdTLR signal requires confirmation. Follow-up continues to five years.
Prof. Ulf Teichgräber: “Both groups fared well. Patients treated with the sirolimus-coated balloon required fewer repeat target-lesion interventions, with separation emerging after the first year. Five-year follow-up will tell us whether this benefit is sustained.”
Dr Manish Doshi, Founder & MD of Concept Medical: “We thank the SIRONA investigators and trial participants. These results expand the randomised evidence base for MagicTouch PTA. We remain committed to generating rigorous long-term data for sirolimus-coated balloon therapy in peripheral artery disease.”
MagicTouch PTA utilises proprietary Nanoluté technology to deliver submicron sirolimus particles in a biocompatible carrier for deep vascular wall penetration. It carries CE marking, received FDA Breakthrough Device designation for below-the-knee disease, and holds FDA IDE approvals for superficial femoral and below-the-knee programmes.
Headquartered in Tampa, Florida, Concept Medical develops precision intravascular drug-delivery platforms. Its MagicTouch franchise is the pioneering and most widely adopted sirolimus-coated balloon platform for coronary and peripheral interventions. MagicTouch and Abluminus portfolios have treated over one million patients globally.
Source: SIRONA (NCT04475783), TCT 2026, JACC: Cardiovascular Interventions, DOI:10.1016/j.jcin.2026.10.020. Funded by Concept Medical; sponsor had no role in data analysis, interpretation or manuscript preparation.
Disclaimer: This release is for medical information only and does not constitute clinical advice.